Exproof Redüksiyon – RC Serisi

 

Exproof Redüksiyon – RC Serisi
Tip : RC TİP REDÜKSİYON
Koruma kodu : I M2 Ex db I Mb/I M2 Ex eb I Mb II 2G Ex db IIC Gb /II 2G Ex eb II Gb II 1D Ex ta IIIC Da
Sertifika : IEP 15 ATEX 0333U
Malzeme : Pirinç, nikel kaplı pirinç, paslanmaz çelik
Standart : EN 60079-0 2012 /60079-1 2007/60079-7 2007 60079-31 2009
O-ring : NBR /Silikon
Koruma Sınıfı : IP66 – IP68
Uygulama : ZONE1, ZONE2, ZONE21, ZONE22, Gaz Grubu IIA. IIB, IIC
Teklif almak, sorularınız ve iletişim için:
WhatsApp ile mesaj gönderin, bizi arayın veya e-posta atın.

Exproof Redüksiyon – RC Serisi - Teknik Datasheet

PDF Görüntüle/İndir

Metrik Diş Exproof Redüksiyon - RC Serisi

Metrik Diş Exproof Redüksiyon – RC Serisi
Product Size Product Code IG (F) GL Min (mm) H (mm) SW (mm)
M16 x 1,5 RCXX/M16m-M12f M12 x 1,5 15 19 22
M20 x 1,5 RCXX/M20m-M12f M12 x 1,5 15 19 25
M20 x 1,5 RCXX/M20m-M16f M16 x 1,5 15 19 25
M25 x 1,5 RCXX/M25m-M16f M16 x 1,5 15 19 30
M25 x 1,5 RCXX/M25m-M20f M20 x 1,5 15 19 30
M32 x 1,5 RCXX/M32m-M20f M20 x 1,5 15 19 36
M32 x 1,5 RCXX/M32m-M25f M25 x 1,5 15 19 36
M40 x 1,5 RCXX/M40m-M25f M25 x 1,5 18 22 45
M40 x 1,5 RCXX/M40m-M32f M32 x 1,5 18 22 45
M50 x 1,5 RCXX/M50m-M32f M32 x 1,5 18 23 55
M50 x 1,5 RCXX/M50m-M40f M40 x 1,5 18 23 55
M63 x 1,5 RCXX/M63m-M40f M40 x 1,5 18 23 70
M63 x 1,5 RCXX/M63m-M50f M50 x 1,5 18 23 70
M75 x 1,5 RCXX/M75m-M50f M50 x 1,5 18 24 85
M75 x 1,5 RCXX/M75m-M63f M63 x 1,5 18 24 85
M90 x 1,5 RCXX/M90m-M63f M63 x 1,5 21 29 100
M90 x 1,5 RCXX/M90m-M75f M75 x 1,5 21 29 100
M110 x 1,5 RCXX/M110m-M75f M75 x 1,5 21 31 120
M110 x 1,5 RCXX/M110m-M90f M90 x 1,5 21 31 120

NPT Diş Exproof Redüksiyon - RC Serisi

NPT Diş Exproof Redüksiyon – RC Serisi
Product Size Product Code IG (F) GL Min (mm) H (mm) SW (mm)
NPT 3/8″ RCXX/N38m-N14f NPT 1/4″ 15 19 22
NPT 1/2″ RCXX/N12m-N14f NPT 1/4″ 15 19 25
NPT 1/2″ RCXX/N12m-N38f NPT 3/8″ 15 19 25
NPT 3/4″ RCXX/N34m-N38f NPT 3/8″ 15 19 30
NPT 3/4″ RCXX/N34m-N12f NPT 1/2″ 15 19 30
NPT 1″ RCXX/N100m-N12f NPT 1/2″ 15 19 36
NPT 1″ RCXX/N100m-N34f NPT 3/4″ 15 19 36
NPT 1 1/4″ RCXX/N114m-N12f NPT 1/2″ 18 22 45
NPT 1 1/4″ RCXX/N114m-N34f NPT 3/4″ 18 22 45
NPT 1 1/4″ RCXX/N114m-N100f NPT 1″ 18 22 45
NPT 1 1/2″ RCXX/N112m-N12f NPT 1/2″ 18 23 55
NPT 1 1/2″ RCXX/N112m-N34f NPT 3/4″ 18 23 55
NPT 1 1/2″ RCXX/N112m-N100f NPT 1″ 18 23 55
NPT 1 1/2″ RCXX/N112m-N114f NPT 1 1/4″ 18 23 55
NPT 2″ RCXX/N200m-N114f NPT 1 1/4″ 18 23 65
NPT 2″ RCXX/N200m-N112f NPT 1 1/2″ 18 23 65
NPT 2 1/2″ RCXX/N212m-N112f NPT 1 1/2″ 28 34 75
NPT 2 1/2″ RCXX/N212m-N200f NPT 2″ 28 34 75
NPT 3″ RCXX/N300m-N200f NPT 2″ 28 36 95
NPT 3″ RCXX/N300m-N212f NPT 2 1/2″ 28 36 95
NPT 4″ RCXX/N400m-N212f NPT 2 1/2″ 28 38 120
NPT 4″ RCXX/N400m-N300f NPT 3″ 28 38 120
Exproof Redüksiyon - RC Serisi - Teknik Çizim
Exproof Redüksiyon - RC Serisi Exproof Redüksiyon – RC ...

Ürünlerimiz hakkında soru sormak ya da fiyat teklifi almak için bizimle iletişime geçebilirsiniz.
Soru Sor / Teklif Al