Exproof Nipel – NP Serisi

 

Exproof Nipel – NP Serisi
Tip : NP TİP NİPEL
Koruma kodu : I M2 Ex db I Mb/I M2 Ex eb I Mb II 2G Ex db IIC Gb /II 2G Ex eb II Gb II 1D Ex ta IIIC Da
Sertifika : IEP 15 ATEX 0333U
Malzeme : Pirinç, nikel kaplı pirinç, paslanmaz çelik
O-ring : NBR / Silikon ( talep üzerine)
Koruma Sınıfı : IP66 – IP68
Uygulama : ZONE1, ZONE2, ZONE21, ZONE22,Gaz Grubu IIA. IIB, IIC
Teklif almak, sorularınız ve iletişim için:
WhatsApp ile mesaj gönderin, bizi arayın veya e-posta atın.

Exproof Nipel – NP Serisi - Teknik Datasheet

PDF Görüntüle/İndir

Metrik Diş Exproof Nipel - NP Serisi

Metrik Diş Exproof Nipel – NP Serisi
Product Size Product Code AG 1 (mm) D (mm) H (mm) GL (mm) GL 1 (mm) SW (mm)
M12 x 1,5 NPXX/M12m-M12m M12 x 1,5 7 48 15 15 18
M16 x 1,5 NPXX/M16m-M16m M16 x 1,5 10 48 15 15 20
M20 x 1,5 NPXX/M20m-M20m M20 x 1,5 14 48 15 15 24
M25 x 1,5 NPXX/M25m-M25m M25 x 1,5 19 50 15 15 32
M32 x 1,5 NPXX/M32m-M32m M32 x 1,5 26 50 15 18 36
M40 x 1,5 NPXX/M40m-M40m M40 x 1,5 34 56 18 18 45
M50 x 1,5 NPXX/M50m-M50m M50 x 1,5 44 58 18 18 55
M63 x 1,5 NPXX/M63m-M63m M63 x 1,5 57 58 18 18 70
M75 x 1,5 NPXX/M75m-M75m M75 x 1,5 69 62 18 21 85
M90 x 1,5 NPXX/M90m-M90m M90 x 1,5 84 68 21 21 100
M110 x 1,5 NPXX/M110m-M110m M110 x 1,5 100 69 21 15 120

NPT Diş Exproof Nipel - NP Serisi

NPT Diş Exproof Nipel – NP Serisi
Product Size Product Code AG 1 (mm) D (mm) H (mm) GL (mm) GL 1 (mm) SW (mm)
NPT 1/4″ NPXX/N14m-M12m M12 x 1,5 7 48 16 15 18
NPT 3/8″ NPXX/N38m-M16m M16 x 1,5 10 48 16 15 20
NPT 1/2″ NPXX/N12m-M20m M20 x 1,5 14 54 21 15 24
NPT 3/4″ NPXX/N34m-M25m M25 x 1,5 19 54 21 15 32
NPT 1″ NPXX/N100m-M32m M32 x 1,5 26 61 26 18 36
NPT 1 1/4″ NPXX/N114m-M40m M40 x 1,5 33 68 28 18 45
NPT 1 1/2″ NPXX/N112m-M50m M50 x 1,5 40 68 28 18 55
NPT 2″ NPXX/N200m-M63m M63 x 1,5 52 68 28 18 70
NPT 2 1/2″ NPXX/N212m-M75m M75 x 1,5 62 85 38 21 85
NPT 3″ NPXX/N300m-M90m M90 x 1,5 75 85 38 21 100
NPT 4″ NPXX/N400m-M110m M110 x 1,5 100 85 38 16 120

NPT Diş Exproof Nipel - NP Serisi

NPT Diş Exproof Nipel – NP Serisi
Product Size Product Code AG 1 (mm) D (mm) H (mm) GL (mm) GL 1 (mm) SW (mm)
NPT 1/4″ NPXX/N14m-N14m NPT 1/4″ 77 50 16 16 18
NPT 1/4″ NPXX/N14m-N38m NPT 3/8″ 12 50 16 16 20
NPT 3/8″ NPXX/N38m-N38m NPT 3/8″ 12 50 16 21 20
NPT 3/8″ NPXX/N38m-N12m NPT 1/2″ 15,5 55 16 21 24
NPT 1/2″ NPXX/N12m-N12m NPT 1/2″ 15,5 62 21 21 24
NPT 1/2″ NPXX/N12m-N34m NPT 3/4″ 19 62 21 21 32
NPT 3/4″ NPXX/N34m-N34m NPT 3/4″ 19 62 21 26 32
NPT 3/4″ NPXX/N34m-N100m NPT 1″ 25 67 21 26 36
NPT 1″ NPXX/N100m-N100m NPT 1″ 25 72 26 28 36
NPT 1″ NPXX/N100m-N114m NPT 1 1/4″ 33 74 26 28 45
NPT 1 1/4″ NPXX/N114m-N114m NPT 1 1/4″ 40 78 28 28 45
NPT 1 1/2″ NPXX/N112m-N112m NPT 1 1/2″ 52 78 28 28 55
NPT 2″ NPXX/N200m-N200m NPT 2″ 62 78 28 38 65
NPT 2 1/2″ NPXX/N212m-N212m NPT 2 1/2″ 75 102 38 38 80
NPT 3″ NPXX/N300m-N300m NPT 3″ 100 102 38 38 95
NPT 4″ NPXX/N400m-N400m NPT 4″ 18 102 38 120
Exproof Nipel - NP Serisi - Teknik Çizim