Exproof Kör Tapa – TK Serisi

Exproof Kör Tapa – TK Serisi
Tip : TK TİP KÖR TAPA
Koruma Kodu : I M2 Ex db I Mb / I M2 Ex eb I Mb II 2G Ex db IIC Gb II 2G Ex eb II Gb II 1D Ex ta IIIC Da
Sertifika : IEP 15 ATEX 0333U
Malzeme : Pirinç, nikel kaplı pirinç, paslanmaz çelik
Standart : EN 60079-0 2012 /60079-1 2007/60079-7 2007 60079-31 2009
O-ring : NBR /Silikon
Koruma Sınıfı : IP66 – IP68
Uygulama : ZONE1, ZONE2, ZONE21, ZONE22, Gaz Grubu IIA. IIB, IIC
Teklif almak, sorularınız ve iletişim için:
WhatsApp ile mesaj gönderin, bizi arayın veya e-posta atın.

Exproof Kör Tapa – TK Serisi - Teknik Datasheet

PDF Görüntüle/İndir

Metrik Diş Exproof Kör Tapa - TK Serisi

Metrik Diş Exproof Kör Tapa – TK Serisi
Product Size Product Code GL Min (mm) H (mm) SW (mm)
M12 x 1,5 TKXX – M12 15 22 17
M16 x 1,5 TKXX – M16 15 22 22
M20 x 1,5 TKXX – M20 15 22 24
M25 x 1,5 TKXX – M25 15 22 30
M32 x 1,5 TKXX – M32 15 22 36
M40 x 1,5 TKXX – M40 15 22 45
M50 x 1,5 TKXX – M50 15 22 55
M63 x 1,5 TKXX – M63 15 22 70
M75 x 1,5 TKXX – M75 15 22 80
M90 x 2 TKXX – M90 20 27 95
M100 x 2 TKXX – M100 20 27 110

NPT Diş Exproof Kör Tapa - TK Serisi

NPT Diş Exproof Kör Tapa – TK Serisi
Product Size Product Code GL Min (mm) H (mm) SW (mm)
NPT 1/4″ TKXX – N14 15 22 15
NPT 3/8″ TKXX – N38 15 22 20
NPT 1/2″ TKXX – N12 15 22 24
NPT 3/4″ TKXX – N34 15 22 27
NPT 1″ TKXX – N100 15 22 35
NPT 1 1/4″ TKXX – N114 18 25 45
NPT 1 1/2″ TKXX – N112 18 25 50
NPT 2″ TKXX – N200 18 25 65
NPT 2 1/2″ TKXX – N212 28 35 75
NPT 3″ TKXX – N300 28 35 90
NPT 4″ TKXX – N400 28 35 115

GAS Diş Exproof Kör Tapa - TK Serisi

GAS Diş Exproof Kör Tapa – TK Serisi
Product Size Product Code GL Min (mm) H (mm) SW (mm)
G 1/4″ TKXX – G14 15 22 18
G 3/8″ TKXX – G38 15 22 22
G 1/2″ TKXX – G12 15 22 25
G 3/4″ TKXX – G34 15 22 32
G 1″ TKXX – G100 15 22 38
G 1 1/4″ TKXX – G114 15 22 45
G 1 1/2″ TKXX – G112 15 22 55
G 2″ TKXX – G200 15 22 65
G 2 1/2″ TKXX – G212 20 27 85
G 3″ TKXX – G300 20 27 95
G 4″ TKXX – G400 20 27 120

PG Diş Exproof Kör Tapa - TK Serisi

PG Diş Exproof Kör Tapa – TK Serisi
Product Size Product Code GL Min (mm) H (mm) SW (mm)
PG7 TKXX – P7 15 22 17
PG9 TKXX – P9 15 22 20
PG 11 TKXX – P11 15 22 25
PG 13,5 TKXX – P13 15 22 25
PG16 TKXX – P16 15 22 27
PG21 TKXX – P21 15 22 35
PG29 TKXX – P29 15 22 42
PG36 TKXX – P36 15 22 55
PG42 TKXX – P42 15 22 60
PG48 TKXX – P48 15 22 65
Exproof Kör Tapa - TK Serisi - Teknik Çizim
Exproof Kör Tapa - TK Serisi Exproof Kör Tapa – TK Se...

Ürünlerimiz hakkında soru sormak ya da fiyat teklifi almak için bizimle iletişime geçebilirsiniz.
Soru Sor / Teklif Al