Exproof Adaptör – AP1 Serisi

 

Exproof Adaptör – AP1 Serisi
Tip : AP1 TİP EX-PROOF ADAPTÖR
Koruma kodu : I M2 Ex db I Mb/I M2 Ex eb I Mb II 2G Ex db IIC Gb /II 2G Ex eb II Gb II 1D Ex ta IIIC Da
Sertifika : IEP 15 ATEX 0333U
Malzeme : Pirinç, nikel kaplı pirinç, paslanmaz çelik
Standart : EN 60079-0 2012 /60079-1 2007/60079-7 2007 60079-31 2009
O-ring : NBR /Silikon
Koruma Sınıfı : IP66 – IP68
Teklif almak, sorularınız ve iletişim için:
WhatsApp ile mesaj gönderin, bizi arayın veya e-posta atın.

Exproof Adaptör – AP1 Serisi - Teknik Datasheet

PDF Görüntüle/İndir

Metrik - NPT Exproof Adaptör - AP1 Serisi

Metrik – NPT Exproof Adaptör – AP1 Serisi
Product Size Product Code IG (F) GL Min (mm) H (mm) SW (mm)
M16 x 1,5 AP1XX/M16m-N14f NPT 1/4″ 15 19 22
M20 x 1,5 AP1XX/M20m-N14f NPT 1/4″ 15 19 25
M25 x 1,5 AP1XX/M25m-N12f NPT 1/2″ 15 19 30
M32 x 1,5 AP1XX/M32m-N12f NPT 1/2″ 15 19 36
M32 x 1,5 AP1XX/M32m-N34f NPT 3/4″ 15 19 36
M40 x 1,5 AP1XX/M40m-N34f NPT 3/4″ 18 22 45
M40 x 1,5 AP1XX/M40m-N100f NPT 1″ 18 22 45
M50 x 1,5 AP1XX/M50m-N100f NPT 1″ 18 23 55
M50 x 1,5 AP1XX/M50m-N114f NPT 1 1/4″ 18 23 55
M63 x 1,5 AP1XX/M63m-N114f NPT 1 1/4″ 18 23 70
M63 x 1,5 AP1XX/M63m-N112f NPT 1 1/2″ 18 23 70
M75 x 1,5 AP1XX/M75m-N112f NPT 1 1/2″ 18 24 85
M75 x 1,5 AP1XX/M75m-N200f NPT 2″ 18 24 85
M90 x 1,5 AP1XX/M90m-N200f NPT 2″ 21 29 100
M90 x 1,5 AP1XX/M90m-N212f NPT 2 1/2″ 31 41 100
M110 x 1,5 AP1XX/M110m-N212f NPT 2 1/2″ 31 41 120
M110 x 1,5 AP1XX/M110m-N300f NPT 3″ 33 43 120

NPT - Metrik Exproof Adaptör - AP1 Serisi

NPT – Metrik Exproof Adaptör – AP1 Serisi
Product Size Product Code IG (F) GL Min (mm) H (mm) SW (mm)
NPT 3/8″ AP1XX/N38m-M12f M12 x 1,5 15 19 22
NPT 1/2″ AP1XX/N12m-M12f M12 x 1,5 15 19 25
NPT 1/2″ AP1XX/N12m-M16f M16 x 1,5 15 19 25
NPT 3/4″ AP1XX/N34m-M16f M16 x 1,5 15 19 30
NPT 3/4″ AP1XX/N34m-M20f M20 x 1,5 15 19 30
NPT 1″ AP1XX/N100m-M20f M20 x 1,5 15 19 36
NPT 1″ AP1XX/N100m-M25f M25 x 1,5 15 19 36
NPT 1 1/4″ AP1XX/N114m-M25f M25 x 1,5 18 22 45
NPT 1 1/4″ AP1XX/N114m-M32f M32 x 1,5 18 22 45
NPT 1 1/2″ AP1XX/N112m-M32f M32 x 1,5 18 23 55
NPT 1 1/2″ AP1XX/N112m-M40f M40 x 1,5 18 23 55
NPT 2″ AP1XX/N200m-M40f M40 x 1,5 18 23 65
NPT 2″ AP1XX/N200m-M50f M50 x 1,5 18 23 65
NPT 2 1/2″ AP1XX/N212m-M50f M50 x 1,5 28 34 75
NPT 2 1/2″ AP1XX/N212m-M63f M63 x 1,5 28 34 75
NPT 3″ AP1XX/N300m-M63f M63 x 1,5 28 36 95
NPT 3″ AP1XX/N300m-M75f M75 x 1,5 28 36 95
NPT 4″ AP1XX/N400m-M75f M75 x 1,5 28 38 120
NPT 4″ AP1XX/N400m-M90f M90 x 1,5 28 38 120
NPT 2″ APXX/N200m-M63f M63 x 1,5 18 40,5 70
NPT 2″ APXX/N200m-M75f M75 x 1,5 18 40,5 80
NPT 2 1/2″ APXX/N212m-M75f M75 x 1,5 28 50,5 80
NPT 2 1/2″ APXX/N212m-M90f M90 x 1,5 28 50,5 95
NPT 3″ APXX/N300m-M90f M90 x 1,5 28 54 95
NPT 3″ APXX/N300m-M110f M110 x 1,5 28 54 115
NPT 4″ APXX/N400m-M110f M110 x 1,5 28 54 120
Exproof Adaptör - AP1 Serisi - Teknik Çizim
Exproof Adaptör - AP1 Serisi Exproof Adaptör – AP1 Se...

Ürünlerimiz hakkında soru sormak ya da fiyat teklifi almak için bizimle iletişime geçebilirsiniz.
Soru Sor / Teklif Al